Technical Articles2022-03-04T06:18:50+00:00
2704, 2021

Application Note by Using Nutech Preconcentrator System for EPA TO-15A Lab Analysis

Application Note by Using Nutech Preconcentrator System for EPA TO-15A Lab Analysis 【Abstract】 By Using three stage cryogenic system + GC/MS technology (Full Scan and/or SIM) 82 VOC compounds (TO15A Mix by Linde) in air was analyzed in a single run. The results show that in 0.5-10.0ppb range the calibration, precision, accuracy, blank and MDL etc. are all

1003, 2021

Study of VOC and Photochemical Ozone Pollution in the Pearl River Delta Region

Study of VOC and Photochemical Ozone Pollution in the Pearl River Delta Region   1 INTRODUCTION 1.1 Background 1.1.1 The rapid economic development in the Pearl River Delta (PRD) Region including Hong Kong Special Administrative Region over the past decade has resulted in changes in the nature of air pollutants emitted from various activities in the region. There has

403, 2021

US EPA Method TO-15 VS US EPA Method TO-14A

US EPA Method TO-15 VS US EPA Method TO-14A Compendium Method TO-15 is significant in that it extends the Compendium Method TO-14A description for using canister-based sampling and gas chromatographic analysis in the following ways: • Compendium Method TO-15 incorporates a multisorbent/dry purge technique or equivalent (see Appendix A) for water management thereby addressing a more extensive set of

1311, 2020

Releases of Fire-Derived Contaminants from Water Pipes Made of Polyvinyl Chloride Polymer

Abstract: In order to assess the human exposure risks from the release of contaminants from water pipes made of polyvinyl chloride (PVC), experiments were carried out by subjecting the PVC pipe material to burning and leaching conditions followed by analysis of the emission and leachate samples. The emissions of burning pipes were analyzed by both infrared spectrometry and gas

2709, 2020

Storage Stability of 66 Volatile Organic Compounds (VOCs) in Silicon-Lined Air Canisters for 30 Days

Storage Stability of 66 Volatile Organic Compounds (VOCs) in Silicon-Lined Air Canisters for 30 Days Abstract The recoveries of 66 volatile organic compounds (VOCs) typically analyzed as part of the United States (U.S.) Environmental Protection Agency’s (EPA’s) Compendium Method TO-15, were evaluated for two commercially available silicon-lined (SL) air canisters. The VOC recoveries were determined both in dry

2509, 2020

Control of VOCs Emissions by Condenser Pre-treatment in a Semiconductor Fab

Control of VOCs Emissions by Condenser Pre-treatment in a Semiconductor Fab Abstract The performance of a modified design of local condensers to pre-treat a variety of volatile organic compounds (VOCs) emitted from the stripping process of a semiconductor fab was tested in this study. The reaction temperature of the condensers was controlled at around 10 ◦C, it is

2509, 2020

Whole Air Canister Sampling and Preconcentration GC-MS Analysis for pptv Levels of Trimethylsilanol in Semiconductor Cleanroom Air

Whole Air Canister Sampling and Preconcentration GC-MS Analysis for pptv Levels of Trimethylsilanol in Semiconductor Cleanroom Air Abstract The costly damage trimethylsilanol (TMS) in cleanrooms exacts on scanner lenses in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts-per-trillion, volume-per-volume of air [pptv] [~ng/m3]. This study

2209, 2020

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air Abstract The following study evaluated the efficacy of using Nutech’s 8900DS preconcentrator in combination with an analytical system based on a 30 m x 0.32 mm x 1.00 µm Rxi-5Sil MS column for analysis of VOCs in whole air. Results were assessed based on five criteria outlined for

2907, 2020

Application Note by Using Nutech 2203 Dilutor for Canister Humidification

Application Note by Using Nutech 2203 Dilutor for Canister Humidification Abstract By using Nutech 2203 Dilutor Liquid Injection function you may do the canister humidification quantitatively and easily. The humidification process will be controlled by computer program and a proprietary adapter is used to make sure the humidification process is going correctly. Introduction USEPA TO-15A and

2307, 2020

Airborne Molecular Contaminants (AMC) / Volatile Organic Compounds Monitoring for Semiconductor Foundry Clean Room Air

Airborne Molecular Contaminants (AMC) / Volatile Organic Compounds Monitoring for Semiconductor Foundry Clean Room Air ABSTRACT Air samples were collected in consecutive days using Summa canisters from semiconductor foundry clean rooms and air entrances. By coupling a NuTech pre-concentrator with an Agilent GC-MS, an optimized method for qualitative and quantitative analysis of VOC compounds was developed.

Go to Top