Application Note by Using Nutech Preconcentrator System for EPA TO-15A Lab Analysis
Application Note by Using Nutech Preconcentrator System for EPA TO-15A Lab Analysis 【Abstract】 By Using three stage cryogenic system + GC/MS technology (Full Scan and/or SIM) 82 VOC compounds (TO15A Mix by Linde) in air was analyzed in a single run. The results show that in 0.5-10.0ppb range the calibration, precision, accuracy, blank and MDL etc. are all
Study of VOC and Photochemical Ozone Pollution in the Pearl River Delta Region
Study of VOC and Photochemical Ozone Pollution in the Pearl River Delta Region 1 INTRODUCTION 1.1 Background 1.1.1 The rapid economic development in the Pearl River Delta (PRD) Region including Hong Kong Special Administrative Region over the past decade has resulted in changes in the nature of air pollutants emitted from various activities in the region. There has
US EPA Method TO-15 VS US EPA Method TO-14A
US EPA Method TO-15 VS US EPA Method TO-14A Compendium Method TO-15 is significant in that it extends the Compendium Method TO-14A description for using canister-based sampling and gas chromatographic analysis in the following ways: • Compendium Method TO-15 incorporates a multisorbent/dry purge technique or equivalent (see Appendix A) for water management thereby addressing a more extensive set of
Releases of Fire-Derived Contaminants from Water Pipes Made of Polyvinyl Chloride Polymer
Abstract: In order to assess the human exposure risks from the release of contaminants from water pipes made of polyvinyl chloride (PVC), experiments were carried out by subjecting the PVC pipe material to burning and leaching conditions followed by analysis of the emission and leachate samples. The emissions of burning pipes were analyzed by both infrared spectrometry and gas
Storage Stability of 66 Volatile Organic Compounds (VOCs) in Silicon-Lined Air Canisters for 30 Days
Storage Stability of 66 Volatile Organic Compounds (VOCs) in Silicon-Lined Air Canisters for 30 Days Abstract The recoveries of 66 volatile organic compounds (VOCs) typically analyzed as part of the United States (U.S.) Environmental Protection Agency’s (EPA’s) Compendium Method TO-15, were evaluated for two commercially available silicon-lined (SL) air canisters. The VOC recoveries were determined both in dry
Control of VOCs Emissions by Condenser Pre-treatment in a Semiconductor Fab
Control of VOCs Emissions by Condenser Pre-treatment in a Semiconductor Fab Abstract The performance of a modified design of local condensers to pre-treat a variety of volatile organic compounds (VOCs) emitted from the stripping process of a semiconductor fab was tested in this study. The reaction temperature of the condensers was controlled at around 10 ◦C, it is
Whole Air Canister Sampling and Preconcentration GC-MS Analysis for pptv Levels of Trimethylsilanol in Semiconductor Cleanroom Air
Whole Air Canister Sampling and Preconcentration GC-MS Analysis for pptv Levels of Trimethylsilanol in Semiconductor Cleanroom Air Abstract The costly damage trimethylsilanol (TMS) in cleanrooms exacts on scanner lenses in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts-per-trillion, volume-per-volume of air [pptv] [~ng/m3]. This study
Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air
Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air Abstract The following study evaluated the efficacy of using Nutech’s 8900DS preconcentrator in combination with an analytical system based on a 30 m x 0.32 mm x 1.00 µm Rxi-5Sil MS column for analysis of VOCs in whole air. Results were assessed based on five criteria outlined for
Application Note by Using Nutech 2203 Dilutor for Canister Humidification
Application Note by Using Nutech 2203 Dilutor for Canister Humidification Abstract By using Nutech 2203 Dilutor Liquid Injection function you may do the canister humidification quantitatively and easily. The humidification process will be controlled by computer program and a proprietary adapter is used to make sure the humidification process is going correctly. Introduction USEPA TO-15A and
Application Note by Using Nutech 2104 Canister Clean System for Sample Train Clean and Certification
Application Note by Using Nutech 2104 Canister Clean System for Sample Train Clean and Certification Abstract By Using Nutech 2104 Canister Clean System, users may do the sample train clean and certification at professional way. The 2104 supplies a pure gas fill and vacuum cycles to clean the sample train automatically, and fill the blank gas,
Airborne Molecular Contaminants (AMC) / Volatile Organic Compounds Monitoring for Semiconductor Foundry Clean Room Air
Airborne Molecular Contaminants (AMC) / Volatile Organic Compounds Monitoring for Semiconductor Foundry Clean Room Air ABSTRACT Air samples were collected in consecutive days using Summa canisters from semiconductor foundry clean rooms and air entrances. By coupling a NuTech pre-concentrator with an Agilent GC-MS, an optimized method for qualitative and quantitative analysis of VOC compounds was developed.
Application Note by Using Nutech Preconcentrator System for TX 85 Target Compounds in Lab Analysis
Application Note by Using Nutech Preconcentrator System for TX 85 Target Compounds in Lab Analysis Abstract By Using three stage cryogenic preconcentration system + GC/MS technology (Full Scan and/or SIM) 85 TX (TCEQ) target VOC compounds (PAMS+TO-15 Mix by Linde and diluted by our lab) in air will be analyzed in a single run.