Analysis of 117 VOCs Compounds by Using Nutech 8910 Preconcentrator System

Application Note: Analysis of 117 VOCs Compounds by Using Nutech 8910 Preconcentrator System 【Abstract】 By Using three stage cryogenic system + GC/MS technology (Full Scan and/or SIM) 117 VOC compounds (TO15 + PAMS + Aldehyde Compounds Mix by Linde) in air be analyzed to check the 8910 instrument performance. The results shows that in 0.1-10.0ppb

By |2021-10-14T06:37:32+00:00October 14th, 2021|Application Notes, Technical Articles|0 Comments

Application Note: A Fast Run for EPA TO-15A by Using Nutech 8910 Preconcentrator System

Application Note: A Fast Run for EPA TO-15A by Using Nutech 8910 Preconcentrator System 【Abstract】 By Using three stage cryogenic system + GC/MS technology (Full Scan and/or SIM) 82 VOC compounds (TO15A Mix by Linde) in air be analyzed in a fast single run performance. The results shows that in 0.1-20.0ppb range the calibration,

Application Note by Using Nutech Preconcentrator System for EPA TO-15A Lab Analysis

Application Note by Using Nutech Preconcentrator System for EPA TO-15A Lab Analysis 【Abstract】 By Using three stage cryogenic system + GC/MS technology (Full Scan and/or SIM) 82 VOC compounds (TO15A Mix by Linde) in air was analyzed in a single run. The results show that in 0.5-10.0ppb range the calibration, precision, accuracy, blank and

Releases of Fire-Derived Contaminants from Water Pipes Made of Polyvinyl Chloride Polymer

Abstract: In order to assess the human exposure risks from the release of contaminants from water pipes made of polyvinyl chloride (PVC), experiments were carried out by subjecting the PVC pipe material to burning and leaching conditions followed by analysis of the emission and leachate samples. The emissions of burning pipes were analyzed by both

By |2020-11-13T05:16:21+00:00November 13th, 2020|Application Notes, Technical Articles|0 Comments

Control of VOCs Emissions by Condenser Pre-treatment in a Semiconductor Fab

Control of VOCs Emissions by Condenser Pre-treatment in a Semiconductor Fab   Abstract The performance of a modified design of local condensers to pre-treat a variety of volatile organic compounds (VOCs) emitted from the stripping process of a semiconductor fab was tested in this study. The reaction temperature of the condensers was controlled at around

By |2020-09-25T08:16:11+00:00September 25th, 2020|Application Notes, Technical Articles|0 Comments

Whole Air Canister Sampling and Preconcentration GC-MS Analysis for pptv Levels of Trimethylsilanol in Semiconductor Cleanroom Air

Whole Air Canister Sampling and Preconcentration GC-MS Analysis for pptv Levels of Trimethylsilanol in Semiconductor Cleanroom Air   Abstract The costly damage trimethylsilanol (TMS) in cleanrooms exacts on scanner lenses in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts-per-trillion, volume-per-volume of air

By |2020-09-25T05:59:39+00:00September 25th, 2020|Application Notes, Technical Articles|0 Comments

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air Abstract The following study evaluated the efficacy of using Nutech’s 8900DS preconcentrator in combination with an analytical system based on a 30 m x 0.32 mm x 1.00 µm Rxi-5Sil MS column for analysis of VOCs in whole air. Results were assessed based on five

By |2020-09-22T08:27:15+00:00September 22nd, 2020|Application Notes, Technical Articles|0 Comments

Application Note by Using Nutech 2203 Dilutor for Canister Humidification

Application Note by Using Nutech 2203 Dilutor for Canister Humidification Abstract By using Nutech 2203 Dilutor Liquid Injection function you may do the canister humidification quantitatively and easily. The humidification process will be controlled by computer program and a proprietary adapter is used to make sure the humidification process is going correctly.

Application Note by Using Nutech 2104 Canister Clean System for Sample Train Clean and Certification

Application Note by Using Nutech 2104 Canister Clean System for Sample Train Clean and Certification Abstract By Using Nutech 2104 Canister Clean System, users may do the sample train clean and certification at professional way. The 2104 supplies a pure gas fill and vacuum cycles to clean the sample train automatically, and

Application Note by Using Nutech Preconcentrator System for TX 85 Target Compounds in Lab Analysis

Application Note by Using Nutech Preconcentrator System for TX 85 Target Compounds in Lab Analysis Abstract By Using three stage cryogenic preconcentration system + GC/MS technology (Full Scan and/or SIM) 85 TX (TCEQ) target VOC compounds (PAMS+TO-15 Mix by Linde and diluted by our lab) in air will be analyzed